C5`C10 |
|
Performance
Measuring Range |
100 to 200 ppm |
200 to 3000 ppm |
|
Number of Pump Strokes |
|
Correction Factor |
|
Sampling Time |
1.5 minutes per pump stroke |
Detecting Limit |
20 ppm (n=2) |
Colour Change |
White → Blackish brown |
Reaction Principle |
Hydorocarbon (C6 + C10) + I2H5 + H2S2O7 → I2
|
Coefficient of Variation |
10% (for 200 to 1000 ppm), 5% (for 1000 to 3000 ppm) |
Shelf Life |
3 Years |
Corrections for temperature & humidity |
Unnecessary |
Store the tubes at cool and dark place. |
Possible coexisting substances and their interferences
(NOTE)
Substance |
Concentration |
Interference |
Change colour by itself to |
Acetylene, Ethylene |
0.1% |
+ |
Blackish brown |
Carbon monoxide |
0.1% |
+ |
Blackish brown |
Other organic solvents |
|
+ |
Blackish brown |
Other substance measurable with this detector tube
Substance |
Correction Factor |
No. of pump strokes |
Measuring Range |
Decane |
2.0 |
1 or 2 |
200 to 6000 ppm |
Heptane |
0.9 |
1 or 2 |
90 to 2700 ppm |
Hexane |
0.8 |
1 or 2 |
80 to 2400 ppm |
Nonane |
1.3 |
1 or 2 |
130 to 3900 ppm |
Octane |
1.0 |
1 or 2 |
100 to 3000 ppm |
Calibration gas generation |
Vaper pressure method |
TLV-TWA |
TLV-STEL |
Explosive range |
- |
- |
- |