Isoamyl alcohol

NO.117
iCH3j2CHCH2CH2OHii-C5H11OHj
Performance
Measuring Range 5 to 300 ppm
Number of Pump Strokes 2
Correction Factor 1
Sampling Time 3 minutes per pump stroke
Detecting Limit 1 ppm (n=2)
Colour Change Yellow → Pale blue
Reaction Principle (CH3 )2CHCH2CH2OH + Cr6+ + H3PO4 → Cr3+
Coefficient of Variation 15% (for 5 to 30 ppm), 10% (for 30 to 300 ppm)
Shelf Life 3 Years
Corrections for temperature & humidity Temperature correction is necessary
Store the tubes at cool and dark place.
Possible coexisting substances and their interferences (NOTE)
Substance Concentration Interference Change colour by itself to
Alcohols   + Pale blue
Calibration gas generation Diffusion tube method
TLV-TWA TLV-STEL Explosive range
100 ppm 125 ppm 1.2 to 9%


Return to previous viewGo to top of page