Methylcychlohexanol |
NO.119 |
Measuring Range | 5 to 100 ppm |
Number of Pump Strokes | 2 |
Correction Factor | 1 |
Sampling Time | 2 minutes per pump stroke |
Detecting Limit | 1 ppm (n=2) |
Colour Change | Yellow → Pale blue |
Reaction Principle | CH3C6H10OH + Cr6++ H3PO4 → Cr3+ |
Coefficient of Variation | 10% (for 5 to 50 ppm), 5% (for 50 to 250 ppm) |
Shelf Life | 2 Years |
Corrections for temperature & humidity | Temperature correction is necessary |
Store the tubes at cool and dark place. |
Substance | Concentration | Interference | Change colour by itself to |
Alcohols | + | Pale blue | |
Aromatic HCs | + | Pale blue |
Calibration gas generation | Vaper pressure method |
TLV-TWA | TLV-STEL | Explosive range |
50 ppm | - | 1% or higher |