Nitrogen oxides

NO.11HA
NO+NO2
Performance
Measuring Range 50 to 2500 ppm
Number of Pump Strokes 1
Correction Factor 1
Sampling Time 1 minute per pump stroke
Detecting Limit 10 ppm (n=1)
Colour Change White → Green
Reaction Principle NO + Cr6+ + H2SO4 →NO2
NO2 + (C6H5)2NH Green product
Coefficient of Variation 10% (for 50 to 400 ppm), 5% (for 400 to 2500 ppm)
Shelf Life 2 Years
Corrections for temperature & humidity Unnecessary
Store the tubes at cool and dark place.
Possible coexisting substances and their interferences (NOTE)
Substance Concentration Interference Change colour by itself to
Hydrogen chloride 500 ppm Unclear demarcation Bluish purple ( 100 ppm)
Ozone 200 ppm Unclear demarcation two layers Brown
sulphur dioxide, Hydrogen sulphide   No No
Calibration gas generation NO2:Permeation tube method
NO:High pressure gas cylinder method
TLV-TWA TLV-STEL Explosive range
NO2: 3 ppm
NO: 25 ppm
NO2 :5 ppm -