Stoddard Solvent |
NO.128 |
Measuring Range | 50 to 8000 mg/m3 |
Number of Pump Strokes | 1 |
Correction Factor | 1 |
Sampling Time | 1.5 minutes per pump stroke |
Detecting Limit | 5 mg/m3 (n=1) |
Colour Change | White → Brown (ring) |
Reaction Principle | Stoddard Solvent + I2O5 + H2S2O7 → I2 |
Coefficient of Variation | 15% (for 50 to 300 mg/m3), 10% (for 300 to 8000 mg/m3) |
Shelf Life | 3 Years |
Corrections for temperature & humidity | Unnecessary |
Store the tubes at cool and dark place. |
Substance | Concentration | Interference | Change colour by itself to |
Carbon monoxide | 0.1% | + | Pale brown (whole layer) |
Acetylene, Hexane, Ethylene | 0.2% | + | Pale brown (whole layer) |
Alcohols, Ketones,Esters | No | Pale brown (whole layer) | |
Aromatic hydrocarbons | + | Dark green |
Calibration gas generation | Vaper pressure method |
TLV-TWA | TLV-STEL | Explosive range |
100 mg/m3 | - | 0.8 % or higher |