Hydrogen cyanide |
NO.12L |
Measuring Range |
|
||||
Number of Pump Strokes |
|
||||
Correction Factor |
|
||||
Sampling Time | 2 minutes per pump stroke | ||||
Detecting Limit | 0.1 ppm (n=5) | ||||
Colour Change | Yellow → Red | ||||
Reaction Principle | 2HCN + HgCl2 → Hg(CN)2+ 2HCl HCl + Base → Chloride product |
||||
Coefficient of Variation | 10% (for 2.5 to 20 ppm), 5% (for 20 to 60 ppm) | ||||
Shelf Life | 2 Years | ||||
Corrections for temperature & humidity | Humidity correction is necessary | ||||
Store the tubes at cool and dark place. |
Substance | Concentration | Interference | Change colour by itself to |
sulphur dioxide | 20 ppm | + | Red |
Hydrogen sulphide | 5 ppm | + | Red |
Substance | Correction Factor | No. of pump strokes | Measuring Range |
Acetone cyanohydrine | 1.15 | 1 | 2.88 to 69 ppm |
Boron trichloride | by scale | 2 | 0.5 to 20 ppm |
Calibration gas generation | Permeation tube method |
TLV-TWA | TLV-STEL | Explosive range |
- | C 4.7 ppm | 5.6 to 40% |