Hydrogen cyanide |
NO.12LL |
Measuring Range | 0.2 to 7 ppm |
Number of Pump Strokes | 2 |
Correction Factor | 1 |
Sampling Time | 2 minutes per pump stroke |
Detecting Limit | 0.05 ppm (n=2) |
Colour Change | Yellow → Pink |
Reaction Principle | 2HCN + HgCl2 → Hg(CN)2 + 2HCl HCl + Base → Chloride product |
Coefficient of Variation | 10% (for 0.2 to 2 ppm), 5% (for 2 to 7 ppm) |
Shelf Life | 2 Years |
Corrections for temperature & humidity | Humidity correction is necessary |
Store the tubes at cool and dark place. |
Substance | Concentration | Interference | Change colour by itself to |
Hydrogen sulphide | 1 ppm | + | Red |
sulphur dioxide | 1 ppm | + | Red |
Calibration gas generation | Permeation tube method |
TLV-TWA | TLV-STEL | Explosive range |
- | C 4.7 ppm | 5.6 to 40% |