CH3CO2C2H5 |
|
Performance
Measuring Range |
0.1 to 1.5% |
Number of Pump Strokes |
1 |
Correction Factor |
1 |
Sampling Time |
2 minutes per pump stroke |
Detecting Limit |
0.01% (n=1) |
Colour Change |
Orange → Dark green |
Reaction Principle |
CH3CO2C2H5 + Cr6+ H2SO4 → Cr3+ |
Coefficient of Variation |
10% (for 0.04 to 0.3 %), 5% (for 0.3 to 1.5 %) |
Shelf Life |
3 Years |
Corrections for temperature & humidity |
Temperature correction is necessary |
Store the tubes at cool and dark place. |
Possible coexisting substances and their interferences
(NOTE)
Substance |
Concentration |
Interference |
Change colour by itself to |
sulphur dioxide |
500 ppm |
+ |
Green |
Hydrogen sulphide |
500 ppm |
+ |
Dark green |
Alcohols, Esters, Ketones |
|
+ |
Dark green |
Propane |
0.2% |
+ |
Dark green (whole layer) |
Aromatic HCs |
500 ppm |
+ |
Dark green |
Other substance measurable with this detector tube
Substance |
Correction Factor |
No. of pump strokes |
Measuring Range |
Vinyl acetate |
Factor: 0.6 |
1 |
0.02 to 0.9% |
Calibration gas generation |
Static gas dilution method |
TLV-TWA |
TLV-STEL |
Explosive range |
400 ppm |
- |
2 to 11.5% |