Butyl acetate |
NO.142 |
Measuring Range | 0.05 to 0.8% |
Number of Pump Strokes | 2 |
Correction Factor | 1 |
Sampling Time | 1.5 minutes per pump stroke |
Detecting Limit | 0.002% (n=2) |
Colour Change | Orange → Dark green |
Reaction Principle | CH3CO2(CH2)3CH3 + Cr6+ H2SO4 → Cr3+ |
Coefficient of Variation | 15% (for 0.01 to 0.2 %), 10% (for 0.2 to 0.8 %) |
Shelf Life | 3 Years |
Corrections for temperature & humidity | Temperature correction is necessary |
Store the tubes at cool and dark place. |
Substance | Concentration | Interference | Change colour by itself to |
sulphur dioxide | 500 ppm | + | Green |
Hydrogen sulphide | 500 ppm | + | Dark green |
Alcohols, Esters, Ketones | + | Dark green | |
Propane | 2000 ppm | + | Dark green (Whole layer) |
Aromatic HCs | 500 ppm | + | Dark green |
Calibration gas generation | Static gas dilution method |
TLV-TWA | TLV-STEL | Explosive range |
150 ppm | 200 ppm | 1.7 to 7.6% |