Isobutyl acetate

NO.144
CH3CO2CH2CH(CH3)2(i-CH3CO2C4H9)
Performance
Measuring Range 10 to 300 ppm
Number of Pump Strokes 2
Correction Factor 1
Sampling Time 4 minutes per pump stroke
Detecting Limit 2 ppm (n=2)
Colour Change Yellow → Blackish brown → Pale blue after few minutes
Reaction Principle CH3CO2CH2CH(CH3)2 + Cr6+ + H2SO4 → Cr3+
Coefficient of Variation 15% (for 10 to 100 ppm), 10% (for 100 to 300 ppm)
Shelf Life 2 Years
Corrections for temperature & humidity Temperature correction is necessary
Store the tubes at cool and dark place.
Possible coexisting substances and their interferences (NOTE)
Substance Concentration Interference Change colour by itself to
Alcohols   + Dark brown PšPale blue
(after few minutes)
Ketones   + Dark brown PšPale blue
(after few minutes)
Esters   + Dark brown PšPale blue
(after few minutes)
Calibration gas generation Diffusion tube method
TLV-TWA TLV-STEL Explosive range
150 ppm - 1.3 to 10.5%


Return to previous viewGo to top of page