Methyl ethyl ketone

NO.152L
CH3COC2H5




Performance
Measuring Range 10 to 120ppm 120 to 384ppm
Number of Pump Strokes 1 1/2
Correction Factor 1 3.2
Sampling Time 2 minutes per pump stroke
Detecting Limit 3ppm (n=1)
Colour Change Yellow → Reddish purple
Reaction Principle 3CH3COC2H5 + (NH2OH)3 H3PO4 → H3PO4
Coefficient of Variation 5% (for 10 to 120ppm)
Shelf Life 2 Years
Corrections for temperature & humidity Temperature correction is necessary
Store the tubes in the refrigerator to keep at 10ºC (50ºF) or below.
Possible coexisting substances and their interferences (NOTE)
Substance Concentration Interference Change colour by itself to
Acetaldehyde   + Reddish purple
Acetone   + Reddish purple
Acetic acid   No No
Ethyl acetate   + No
Diethyl ether 20 ppm + No
Trichloroethylene   No No
Toluene   No No
Hexane   No No
Methanol 50 ppm + No
Calibration gas generation Diffusion tube method
TLV-TWA TLV-STEL Explosive range
200 ppm 300 ppm 1.7 to 11.4%


Return to previous viewGo to top of page