Methyl isobutyl ketone |
NO.153L |
Measuring Range | 2.5 to 50ppm | 50 to 130ppm |
Number of Pump Strokes | 1 | 1/2 |
Correction Factor | 1 | 2.6 |
Sampling Time | 2 minutes per pump stroke | |
Detecting Limit | 1.5ppm (n=1) | |
Colour Change | Pale yellow → Pale blue | |
Reaction Principle | (CH3)2CHCH2COCH3+ Cr6+ + H3PO4 → Cr3+ | |
Coefficient of Variation | 10% (for 2.5 to 10ppm), 5% (for 10 to 50ppm) | |
Shelf Life | 1 Year | |
Corrections for temperature & humidity | Temperature correction is necessary | |
Store the tubes at cool and dark place. |
Substance | Concentration | Interference | Change colour by itself to |
Acrolein | 5 ppm | No | Pale blue(20 ppm) |
Acetone | No | No | |
Acetic acid | No | No | |
Ethyl acetate | 5ppm | + | Pale blue |
Diethyl ether | + | Pale blue | |
Toluene | 5ppm | + | White |
Halogenated hydrocarbons | No | No | |
Hexane | 15ppm | + | White(15 ppm) |
Benzene | No | No | |
Methanol | 5ppm | + | Pale blue(10 ppm) |
Methyl ethyl ketone | 5ppm | + | White(5 ppm) |
Calibration gas generation | Diffusion tube method |
TLV-TWA | TLV-STEL | Explosive range |
50 ppm | 75 ppm | 1.2 to 8% |