Methyl isobutyl ketone

NO.153L
(CH3)2CHCH2COCH3
Performance
Measuring Range 2.5 to 50ppm 50 to 130ppm
Number of Pump Strokes 1 1/2
Correction Factor 1 2.6
Sampling Time 2 minutes per pump stroke
Detecting Limit 1.5ppm (n=1)
Colour Change Pale yellow → Pale blue
Reaction Principle (CH3)2CHCH2COCH3+ Cr6+ + H3PO4 → Cr3+
Coefficient of Variation 10% (for 2.5 to 10ppm), 5% (for 10 to 50ppm)
Shelf Life 1 Year
Corrections for temperature & humidity Temperature correction is necessary
Store the tubes at cool and dark place.
Possible coexisting substances and their interferences (NOTE)
Substance Concentration Interference Change colour by itself to
Acrolein 5 ppm No Pale blue(20 ppm)
Acetone   No No
Acetic acid   No No
Ethyl acetate 5ppm + Pale blue
Diethyl ether   + Pale blue
Toluene 5ppm + White
Halogenated hydrocarbons   No No
Hexane 15ppm + White(15 ppm)
Benzene   No No
Methanol 5ppm + Pale blue(10 ppm)
Methyl ethyl ketone 5ppm + White(5 ppm)
Calibration gas generation Diffusion tube method
TLV-TWA TLV-STEL Explosive range
50 ppm 75 ppm 1.2 to 8%


Return to previous viewGo to top of page