Hydrogen fluoride

NO.17
HF
Performance
Measuring Range
0.25 to 0.5 ppm 0.5 to 20 ppm 20 to 100 ppm
Number of Pump Strokes
7 4 1
Correction Factor
1/2 1 5
Sampling Time 45 seconds per pump stroke
Detecting Limit 0.1 ppm (n=7)
Colour Change Yellow → Brownish Pink
Reaction Principle Hydrogen fluoride reacts with indicator to produce brownish pink colour.
HF + Indicator → Chemical reaction compound
Coefficient of Variation 10% (for 0.5 to 5 ppm), 5% (for 5 to 20 ppm)
Shelf Life 3 Years
Corrections for temperature & humidity Humidity correction is necessary
Store the tubes at cool and dark place.
Possible coexisting substances and their interferences (NOTE)
Substance Concentration Interference Change colour by itself to
Hydrogen chloride, Nitric acid 1/5 time + Brownish pink
Chlorine, Nitrogen dioxide 1/10 time + Brownish pink
Other substance measurable with this detector tube
Substance Correction Factor pump stroke Temperature Absolute Humidity Colour Change
Fluorine 2.5 1 20ºC (68ºF) 9 mg/L Brown
1.0 1 20ºC (68ºF) 3 mg/L
Calibration gas generation Permeation tube method
TLV-TWA TLV-STEL Explosive range
0.5ppm C2 ppm -