N,N-Dimethyl acetamide

NO.184
CH3CON(CH3)2
Performance
Measuring Range
1.5 to 5 ppm 5 to 60 ppm 60 to 240 ppm
Number of Pump Strokes
4 2 1
Correction Factor
0.3 1 4
Sampling Time 2 minutes per pump stroke
Detecting Limit 0.5 ppm (n=4)
Colour Change Pink → Pale yellow
Reaction Principle CH3CON(CH3)2 + NaOH → R-NH2
2R-NH2 + H2SO4 → (R-NH2)2SO4
Coefficient of Variation 15% (for 2 to 10 ppm), 10% (for 10 to 30 ppm)
Shelf Life 3 Years
Corrections for temperature & humidity Temperature correction is necessary
Store the tubes at cool and dark place.
Possible coexisting substances and their interferences (NOTE)
Substance Concentration Interference Change colour by itself to
Amines   + Pale yellow
Ammomia   + Pale yellow
Hydrazine   + Pale yellow
Calibration gas generation Diffusion tube method
TLV-TWA TLV-STEL Explosive range
10 ppm - -


Return to previous viewGo to top of page