Carbon monoxide

NO.1H
CO
Performance
Measuring Range
0.1 to 0.2% 0.2 to 5.0% 5.0 to10.0%
Number of Pump Strokes
2 1 1/2
Correction Factor
1/2 1 2
Sampling Time 1.5 minutes per pump stroke
Detecting Limit 0.02% (n=2)
Colour Change White → Blackish brown
Reaction Principle 5CO + I2O5 + H2S2O7 → I2
Coefficient of Variation 10% (for 0.2 to 1.0 %), 5% (for 1.0 to 5.0 %)
Shelf Life 3 Years
Corrections for temperature & humidity Unnecessary
Store the tubes at cool and dark place.
Possible coexisting substances and their interferences (NOTE)
Substance Concentration Interference Change colour by itself to
Acetylene 0.3% + Blackish brown
Olefins 2/3 time + Brown
Butane 1% + Pale brown (whole layer)
Propane 20% + No
Hexane 0.3% + Pale brown (whole layer)
Calibration gas generation High pressure gas cylinder method
TLV-TWA TLV-STEL Explosive range
25 ppm - 12.5 to 74%


Return to previous viewGo to top of page