Carbon monoxide

NO.1HH
CO
Performance
Measuring Range
1 to 2% 2 to 40%
Number of Pump Strokes
1 1/2
Correction Factor
1/2 1
Sampling Time 1 minute per 1/2 pump stroke
Detecting Limit 0.5% (n=1)
Colour Change White → Blackish brown
Reaction Principle 5CO + I2O5 + H2S2O7 → I2
Coefficient of Variation 10% (for 2 to 15 %), 5% (for 15 to 40 %)
Shelf Life 3 Years
Corrections for temperature & humidity Unnecessary
Store the tubes at cool and dark place.
Possible coexisting substances and their interferences (NOTE)
Substance Concentration Interference Change colour by itself to
Acetylene 0.2% Puls error Dark brown
Olefines
(Ethylene, Propylene)
2/3 Puls error Brown
Butane 1% Puls error Pale brown (whole layer)
Propane 20% Puls error
Calibration gas generation High pressure gas cylinder method
TLV-TWA TLV-STEL Explosive range
25 ppm - 12.5 to 74%


Return to previous viewGo to top of page