Carbon monoxide |
NO.1La |
Measuring Range |
|
||||
Number of Pump Strokes |
|
||||
Correction Factor |
|
||||
Sampling Time | 2 minutes per pump stroke | ||||
Detecting Limit | 2 ppm (n=3) | ||||
Colour Change | Yellow → Blackish brown | ||||
Reaction Principle | CO + Na2Pd(SO3)2 → Pd + CO2 + SO2+Na2SO3 | ||||
Coefficient of Variation | 10% (for 25 to 100 ppm), 5% (for 100 to 500 ppm) | ||||
Shelf Life | 3 Years | ||||
Corrections for temperature & humidity | Temperature correction is necessary | ||||
Store the tubes at cool and dark place. |
Substance | Concentration | Interference | Change colour by itself to |
Acetylene | 1/50 time | + | Dark brown |
Ethylene | 2000 ppm | No | Brown (whole layer) |
Hydrogen | 5000 ppm | + | Dark brown (whole layer)(1%) |
sulphur dioxide | 1/10 time | + | Blackish brown |
Nitrogen dioxide | 40 ppm | + | Red (60 ppm) |
Carbon disulphide | 1/50 time | + | Dark brown |
Halogens | 1/5 time | + | Dark brown |
Mercaptans | 1/5 time | + | Dark brown |
Hydrogen sulphide | 1/5 time | + | Dark brown |
Calibration gas generation | High pressure gas cylinder method |
TLV-TWA | TLV-STEL | Explosive range |
25 ppm | - | 12.5 to 74% |