Methyl Iodide

NO.230
CH3I
Performance
Measuring Range 0.5 to 1ppm 1 to 20ppm 20 to 46ppm 46 to 108ppm
Number of Pump Strokes 4 2 1 1/2
Correction Factor 0.5 1 2.3 5.4
Sampling Time 1.5 minutes per pump stroke
Detecting Limit 0.2ppm (n=4)
Colour Change White → Gray
Reaction Principle CH3I + I2O5 + V2O5 + H2SO4 → I2
I2 + 3,3,5,5-Tetramethylbenzidine вк Reaction Products
Coefficient of Variation 5% (for 1 to 20ppm)
Shelf Life 1 Year
Corrections for temperature & humidity Temperature correction is necessary
Store the tubes in the refrigerator to keep at 10ºC (50ºF) or below.
Possible coexisting substances and their interferences (NOTE)
Substance Concentration Interference Change colour by itself to
Chlorine 1/1 + (Two layers) Brown (turns pale blue after a few minutes)
Nitrogen dioxide 1/1 (Two layers) Pink
Methyl bromide 30 ppm No No
Dichloromethane 50 ppm No No
Carbon dioxide 1% No No
Calibration gas generation Diffusion tube method
TLV-TWA TLV-STEL Explosive range
2 ppm - -


Return to previous viewGo to top of page