sulphuric acid

NO.35
H2SO4
Performance
Measuring Range 0.5 to 5 mg/m3
Number of Pump Strokes 5
Correction Factor 1
Sampling Time 1 minute per pump stroke
Detecting Limit 0.2 mg/m3(n=5)
Colour Change Pale yellow → Reddish purple
Reaction Principle H2SO4 + BaCl2 ��2HCl
HCl+Base ��Chloride
Coefficient of Variation 10% (for 0.5 to 2 mg/m3), 5% (for 2 to 5 mg/m3)
Shelf Life 2 Years
Corrections for temperature & humidity Temperature correction is necessary
Store the tubes at cool and dark place.
Possible coexisting substances and their interferences (NOTE)
Substance Concentration Interference Change colour by itself to
Hydrogen chloride �� 0.05 ppm + Reddish purple
Chlorine �� 0.8 ppm + Reddish purple
sulphur dioxide   No No
Nitrogen dioxide �� 1 ppm + Reddish purple
Hydrogen fluoride �� 0.1 ppm + Reddish purple
Calibration gas generation Vaper pressure method
TLV-TWA TLV-STEL Explosive range
0.2mg/m3 - -


Return to previous viewGo to top of page