Hydrogen sulphide |
NO.4HH |
Measuring Range |
|
||
Number of Pump Strokes |
|
||
Correction Factor |
|
||
Sampling Time | 45 seconds per pump stroke | ||
Detecting Limit | 0.01% (n=1) | ||
Colour Change | Pale Blue → Blackish Brown | ||
Reaction Principle | H2S + CuSO4 → CuS + H2SO4 | ||
Coefficient of Variation | 10% (for 0.1 to 0.6 %), 5% (for 0.6 to 2 %) | ||
Shelf Life | 3 Years | ||
Corrections for temperature & humidity | Unnecessary | ||
Store the tubes at cool and dark place. |
Substance | Concentration | Interference | Change colour by itself to |
Ammonia | Two layers (Dark brown & dark blue) |
Dark blue | |
sulphur dioxide | 0.5% | No | |
Mercaptans | 1 % | + | No |
Calibration gas generation | High pressure gas cylinder method |
TLV-TWA | TLV-STEL | Explosive range |
10 ppm | 15 ppm | 4.0 to 44% |