Phosphine

NO.7
PH3
Performance
Measuring Range
2.5 to 5 ppm 5 to 50 ppm 50 to 100 ppm
Number of Pump Strokes
4 2 1
Correction Factor
1/2 1 2
Sampling Time 1.5 minutes per pump stroke
Detecting Limit 0.5 ppm (n = 4)
Colour Change White → Pale yellow
Reaction Principle 2PH3 + 6HgCl2 + 3H2O → Hg3P2 3HgCl23H2O+6HCl
Coefficient of Variation 10% (for 5 to 10 ppm), 5% (for 10 to 50 ppm)
Shelf Life 3 Years
Corrections for temperature & humidity Unnecessary
Store the tubes at cool and dark place.
Possible coexisting substances and their interferences (NOTE)
Substance Concentration Interference Change colour by itself to
Arsine 20 ppm + Brown
Hydrogen selenide 20 ppm + Brown
Hydrogen sulphide 10 ppm + Dark brown
Calibration gas generation High pressure gas cylinder method
TLV-TWA TLV-STEL Explosive range
0.3 ppm 1 ppm -


Return to previous viewGo to top of page