tert-Butyl mercaptan

NO.75L
(CH3)3CSH
Performance
Measuring Range
0.5 to 1 mg/m3 1 to 15 mg/m3 15 to 30 mg/m3
Number of Pump Strokes
2 1 1/2
Correction Factor
1/2 1 2
Sampling Time 1 minute per pump stroke
Detecting Limit 0.1 mg/m3 (n=2)
Colour Change Yellow → Pink
Reaction Principle (CH3)3CSH +HgCl2 → (CH3)3CSHgCl + HCl
HCl + Basic compounds → Chlorides
Coefficient of Variation 10% (for 1 to 4 mg/m3), 5% (for 4 to 15 mg/m3)
Shelf Life 2 Years
Corrections for temperature & humidity Temperature correction is necessary
Store the tubes in the refrigerator to keep at 10ºC (50ºF) or below.
Possible coexisting substances and their interferences (NOTE)
Substance Concentration Interference Change colour by itself to
Hydrogen sulphide   + Pink
Other mercaptans   + Pink
Dimethyl disulphide   No No
Other substance measurable with this detector tube
Substance Correction Factor No. of pump strokes Measuring Range
2-Mercaptoethanol 0.5 1 0.5 to 7.5 ppm
Calibration gas generation Diffusion tube method
TLV-TWA TLV-STEL Explosive range
- - -