Tetrahydrothiophene |
NO.76M |
Measuring Range | 10 to 100 mg/m3 |
Number of Pump Strokes | 2 |
Correction Factor | 1 |
Sampling Time | 1.5 minutes per pump stroke |
Detecting Limit | 2 mg/m3 (n=2) |
Colour Change | Pink → Pale Yellow |
Reaction Principle | C4H8S + MnO4 (Pink) → Pale Yellow Product |
Coefficient of Variation | 10% (for 10 to 30 mg/m3), 5% (for 30 to 100 mg/m3) |
Shelf Life | 2 Years |
Corrections for temperature & humidity | Temperature correction is necessary |
Store the tubes at cool and dark place. |
Substance | Concentration | Interference | Change colour by itself to |
Ethyl mercaptan | 2 ppm | No | Pale pink (whole layer) |
Ethylene | 2000 ppm | No | Pale pink (whole layer) |
Propylene | 1000 ppm | No | Pale pink (whole layer) |
Methanol | 1000 ppm | No | Pale pink (whole layer) |
Hydrogen sulphide | 80 ppm | No | Pale pink (whole layer) |
1-Butene | 1000 ppm | No | Pale pink (whole layer) |
tert-Butyl Mercaptan | 10 mg/m3 | No | Pale pink (whole layer) |
Calibration gas generation | Diffusion tube method |
TLV-TWA | TLV-STEL | Explosive range |
- | - | - |