Phosphine

NO.7H
PH3
Performance
Measuring Range
200 to 2500 ppm 2500 to 5500 ppm
Number of Pump Strokes
1 1/2
Correction Factor
1 2.2
Sampling Time 1 minutes per pump stroke
Detecting Limit 5 ppm (n =1)
Colour Change Yellow → Dark brown
Reaction Principle Phosphine reacts with palladium to produce blackish discolouration
Coefficient of Variation 10% (for 200 to 800 ppm), 5% (for 800 to 2500 ppm)
Shelf Life 2 Years
Corrections for temperature & humidity Temperature correction is necessary
Store the tubes at cool and dark place.
Possible coexisting substances and their interferences (NOTE)
Substance Concentration Interference Change colour by itself to
Ammonia 2500 ppm No No
Carbon monoxide   + Dark brown
Carbon dioxide 2% No +
Calibration gas generation High pressure gas cylinder method
TLV-TWA TLV-STEL Explosive range
0.3 ppm 1 ppm -


Return to previous viewGo to top of page