Cl2 |
![](/files/images/icons/arrow_left_48.png) |
Performance
Measuring Range |
|
Number of Pump Strokes |
|
Correction Factor |
|
Sampling Time |
1.5 minutesa per 1/2 pump stroke |
Detecting Limit |
0.05% (n=1) |
Colour Change |
Reddish purple → Yellow |
Reaction Principle |
Cl2 + Indicator → Yellow products |
Coefficient of Variation |
10% (for 0.5 to 3 %), 5% (for 3 to 10 %) |
Shelf Life |
3 Years |
Corrections for temperature & humidity |
Unnecessary |
Store the tubes at cool and dark place. |
Possible coexisting substances and their interferences
(NOTE)
Substance |
Concentration |
Interference |
Change colour by itself to |
Hydrogen chloride |
|
+ |
Pink |
Nitric acid |
|
+ |
Pink |
Other substance measurable with this detector tube
Substance |
Correction Factor |
No. of pump strokes |
Measuring Range |
Hydrogen chloride |
3.0 |
1/2 |
1.5 to 30 % |
Calibration gas generation |
High pressure gas cylinder method |
TLV-TWA |
TLV-STEL |
Explosive range |
0.5 ppm |
1 ppm |
- |