"This product is no longer available."

GasCheck R2pc is designed specifically for the detection and measurement of refrigerant gas leaks. Its unique sensing system and inbuilt pump and flow management system enables high sensitivity and rapid response to the smallest of leaks - 0.2 gm/yr.

Robust and reliable, GasCheck R2pc can be switched to display leak rates in gm/yr or ppm. Leak rate measurements are continuously updated allowing the leak to be accurately located and the leak rate exponential measured.

Obtaining a direct leak rate measurement and locating the source is a simple one-handed operation. A detected leak triggers the flashing LED and loud audible alarm, clearly indicating the leak present.

The instrument's unique compensating circuit automatically allows for background levels of CFC's to be subtracted out of the response, as well as limiting temperature and humidity changes to ensure that hydrocarbons are accurately detected. The response characteristics of each gas group are held in the instrument's memory.

Continuous operation is achieved from the mains power supply or via rechargeable batteries (typical battery life 5 hours). Ion Science recommends GasCheck is left plugged into the mains power supply at all times when not in use to maintain optimal sensor performance.

 

 

KEY FEATURES

  • Applications
    • Gas Supply
    • Refrigeration
    • Automotive
    • Air Conditioning
  • Unique sensing system for refrigerant gas leak detection
  • Highly sensitive
  • Rapid response
  • Choice of display, gm/yr and ppm
  • Automatically compensates for background levels of CFC's
  • Measurement mode for finding and holding peak readings
  • Audible and visual alarm
  • Handheld and light weight

 

SPECIFICATIONS

 Detector
Composite microprocessor controlled ceramic with low sensitivity to interfering gases such as alcohol
 Minimum Detectable Level 
1.3 x 10-6ml/sec, 5 ppm, 0.2 gm/yr (R134a)
 Detects All CFC, HFC and HCFC gases
 Operation Mains: 110 - 240 VAC
Batteries: 4 x AA NiMH typical 5 hrs life per recharge
NB: It is recommended that the instrument is kept on the mains at all times when not in use
 Response 1 second, with a 5 second clear down (Dependent on leak size detected)
 Alarm Level
15 gm/yr (R134a and equivalent sensitivity gases)
 Probes Standard 100 mm, Long 300 mm, Flex and stay
 Dimensions Instrument with probe: 385 mm x 60 mm x 50 mm, 15.2" x 2.4" x 2"
Standard Case: 420 mm x 320 mm x 97 mm, 16.5" x 12.5" x 3.8"
 Weight
Instrument: 0.4 kg or 0.9 lb
Packed: 1.9 kg or 4.2 lb

 