Titan 2
The Titan 2 is a fixed benzene gas monitor designed for continuous, real-time monitoring in high-risk industrial environments. With industry-leading detection sensitivity down to 0.02 ppm, it protects workers from one of the most dangerous airborne carcinogens found in petrochemical and manufacturing operations. Powered by Ion Science’s advanced MiniPID T2 sensor and housed in a rugged IP65-rated enclosure, the Titan 2 delivers dependable performance in dusty, humid, and ATEX-zoned environments.
List of Benefits
- Benzene-specific detection from 0.02 to 20 ppm
- Fast response time with full readings in 60 seconds
- MiniPID T2 10.0 eV sensor for enhanced accuracy and stability
- Modular, plug-and-play service cartridge
- IP65-rated with ATEX, IECEx, and QPS approvals
- 4–20 mA and RS485 Modbus connectivity options
- Ideal for oil and gas, chemical processing, bulk storage, and asphalt production
Engineered for Accuracy and Speed
The Titan 2 delivers real-time benzene concentration data with high sensitivity and selectivity. It eliminates interference from similar compounds like toluene, xylene, and methane, making it ideal for complex gas environments. It samples once per minute, displaying results on a clear digital screen with LED status indicators and visual alarms for live monitoring.
Built for Harsh Industrial Conditions
The IP65-rated enclosure protects the unit from dust and water ingress, while internally regulated heating ensures stable operation in a wide temperature range. The Titan 2 is certified for use in ATEX-zoned environments, offering consistent performance in extreme conditions. It is suitable for applications where benzene exposure is a concern, including oil refineries, chemical plants, bitumen and asphalt production, and bulk fuel storage facilities.
Modular Design with Seamless Integration
Installation and maintenance are simple thanks to the Titan 2's modular, plug-and-play design. The service module can be swapped out without disrupting operations, helping reduce downtime. It offers both 4–20 mA and RS485 Modbus communication, allowing easy integration into existing control or monitoring systems. Internal data storage also enables trend analysis and compliance tracking.
| Specification | Detail Description |
|---|---|
| Sensor type | MiniPID T2 10.0 eV |
| Selectivity | Benzene-specific within petrochemical matrix |
| Detection range | 0.02 to 20 ppm |
| Resolution | 0.01 ppm (10 ppb) |
| Sampling frequency | 1 sample per minute |
| Lower detection limit | 0.02 ppm (20 ppb) |
| Accuracy | ±50 ppb or ±10%, whichever is greater |
| Temperature stability | Internally heated |
| Flow rate | ≥100 ml/min |
| Display | 64 x 128 pixel graphical LCD with backlight and LED indicators |
| Menu control | Two magnetic switches |
| Operating temperature | -20°C to +50°C (recommended) |
| Approvals | ATEX, IECEx, and QPS certified (Ex db IIB+H2 T4 Gb, -20°C to +55°C) |
| Ingress protection | IP65 |
| Humidity | 0 to 99% RH |
| Service interval | 6 or 12 months (depending on component) |
| Power supply | 24 V DC (nominal), 19–32 V DC range |
| Power draw | 3.2 A (recommended), varies with input voltage |
| Communication | Isolated 4–20 mA, Isolated RS485 Modbus (ASCII or RTU), Micro USB for PC connection |
| Data storage | 2 GB MMC (minimum six months) |
| Relay outputs | Two isolated, voltage-free, 24 V DC @ 1.25 A |
| Cable entry | Two 3/4" NPT gland threads |
| Sample line | Max 10 m, PTFE (6 mm OD, 4 mm ID) |
| Weight | 15 kg |
| Dimensions | 219 x 219 x 172 mm |
FAQs
If you have any questions related to this product, please view our frequently asked questions.