F-Guard IR3 H2-HD

The Gastech F-Guard-lR3-H2-HD flame detector provides ultra-fast response, high performance and reliable detec­tion of hydrogen (H2) fires

List of Benefits

  • High immunity to false alarm
  • Ultra-fast detection mode detection within 40 milliseconds for Hydrogen fireballs or explosions
  • Hydrogen flame detection
  • High sensitivity -up to 100 ft.(30m)
  • HD video output with Automatic HD video recording of fire events
  • Data/Event logger -alarms, faults and other relevant events are logged to non-volatile memory
  • Ethernet communication - in addition to the standard methods, such as 4-20mA and Modbus
  • Built-in-Test (BIT) -Automatic and manual internal self-test of window cleanliness and the overall operation of the detector
  • Window heater to avoid condensation and icing
  • Tilt mounting bracket can be connected either above or below the detector.

 
The de­tector addresses slow growing fires as well as fast eruptions of fire using improved IR3 technology. The detector operates in all weather and light con­ditions. In addition, the detector provides high-definition (HD) video output of the monitored area with clear imaging of a fire event and of personnel at distanc­es up to 100 ft. (30m). This allows the rescue team to be aware of the exact situation before entering the hazard­ous area. The detector automatically records video of fire event (1 minute pre- and up to 3 minutes post-alarm initiation). These features, along with the built-in event logger, provide ad­ditional means to study the cause and development of fire events
SpecificationDetail Description
DETECTION TIME AND DISTANCE 4Oms for fast burst of explosion O.7s for 320 (O.8m) hydrogen fire at 0-100 ft. (O-3Om)
FIELD OF VIEW 90° Horizontal, 75° Vertical
TIME DELAY 0-30 seconds (Adjustable)
BUILT-IN TEST Automatic and Manual
HD VIDEO Allows clear imaging of fire and people at 100 ft. (3Om) distance
VIDEO RECORDING OF ALARM EVENTS 1-minute pre-event and 3 minutes post-event
SYSTEM INTEGRATION ONVIF (Open Network Video Interface Forum)
OPERATING VOLTAGE 24 VDC nominal (18-32 VDC)
CURRENT CONSUMPTION Standby
Maximum 25OmA all systems in operation (including window heater)
ELECTRICAL ENTRIES 2x conduit entries 3/4" 14NPT or M25x1.5
WIRING 12-2OAWG (2.5-O.35mm2)
RELAYS Volt-free contacts rated 2A at 30 VDC Alarm - normally open Fault - normally closed
INDICATION Tri-color LED
MODBUS RTU compatible on RS-485
DIGITAL (FOR VIDEO) IP network IEEE 802.3 10Base-t
COMPOSITE VIDEO NTSC or PAL
MECHANICAL SPECS 7.87 x 5.12 x 5.12" (200x130x130mm)
TEMPERATURE RANGE Operating
HUMIDITY Up to 99% (RH), non-condensing
INGRESS PROGRESSION IP66 & 67; NEMA 250 4X & 6P
APPROVALS (Explosion proof) ATEX
Ex db eb IIC T5 Gb -55°C
IIIC T95°C Db -55°C
IIC T5 Gb -55°C
IIIC T105°C Db -55°C
Class I, Div. 1, Groups B, C & D; Class II, Div. 1, Groups E, F & G; Class III
PERFORMANCE (PENDING) ANSI FM 3260
FUNCTIONAL SAFETY (PENDING) SIL2, per IEC 61508
ACCESSORIES Weather shield
WARRANTY 5 years
 

Share this