RI-415
Portable Infrared Gas Monitor
i
This product has been discontinued and is no longer available. In many cases we can still service and calibrate it. Talk to our team about spares or alternatives.
The RI-415 is a portable NDIR hydrocarbon or methane detector that accurately measures gas levels even in nitrogen and inert environments. With auto-ranging from 0-100% LEL to 0-100% Volume, it features explosion-proof and intrinsically safe construction.
KEY BENEFITS
- Measures from higher concentrations (vol%) down to lower concentrations (%LEL)
- Reliable NDIR method works in N2 and inert gas atmospheres
- Explosion-proof detector with intrinsically safe circuit and pump
- Automatic ranging between 0-100% LEL and 0-100% Volume
- Indication accuracy within +/-5% of reading
+ more in the Description tab below
Reliable infrared HC and methane detection in inert atmospheres
The RI-415 is a portable HC or CH4 detector. Its NDIR sensor style provides accurate detection of hydrocarbon or methane gas levels even in nitrogen and inert environments where catalytic sensors cannot operate.
The measuring ranges are 0-100% Volume and 0-100% LEL with automatic ranging, so the instrument switches range as concentrations change. Explosion-proof and intrinsically safe construction means it can be used safely in demanding environments.
Typical applications include measuring gas concentrations in the tanks of LNG and LPG carriers and in crude oil tankers, with a built-in pump and coiled sampling hose for remote sampling.
Benefits
- Measures from higher concentrations (vol%) down to lower concentrations (%LEL)
- Reliable NDIR method works in N2 and inert gas atmospheres
- Explosion-proof detector with intrinsically safe circuit and pump
- Automatic ranging between 0-100% LEL and 0-100% Volume
- Indication accuracy within +/-5% of reading
- Fast response within 30 seconds (T90)
- Approximately 50 hours of continuous operation
- Available in HC or CH4 versions
- Supplied with carrying case, coiled hose and batteries
Gas detected
HC (HC version) or CH4 (CH4 version)
Detection principle
NDIR (non-dispersive infrared)
Detection range
0.0-100.0% LEL, 0-100% Vol (auto)
Indication accuracy
Within +/-5% of reading
Response time
Within 30 seconds (T90)
Ambient temp/humidity
-10 to 40 degrees C, below 90% RH, non-condensing
Continuous operation
Approx. 50 hours (at 20 C, no alarm, no backlight)
Power source
4 C-size alkaline dry cells or optional Ni-Cad
Dimensions
Approx. 80 (H) x 200 (W) x 142 (D) mm
Weight
Approx. 2 kg
Standard accessories
Carrying case with shoulder strap, batteries, absorbent cotton, 1 m coiled hose
The NDIR (non-dispersive infrared) sensor accurately detects HC or CH4 even in nitrogen and inert environments, where catalytic combustion sensors would not function.
The RI-415 measures 0-100% LEL and 0-100% Volume with automatic ranging, so it covers both low and high concentrations.
Yes. The detector is explosion proof, and the other electrical circuitry and pump use an intrinsically safe design, so it can be used safely in demanding environments.
It is used to measure gas concentrations in the tanks of LNG and LPG carriers and in crude oil tankers.
It offers approximately 50 hours of continuous operation on four C-size alkaline dry cells, with optional Ni-Cad batteries available.
Trusted by







Contact Us
Can’t find what you’re looking for? Our team is happy to help.