Skip to main contentSkip to footer

S-Guard-CO2

Infrared Gas Transmitter

i

This product has been discontinued and is no longer available. In many cases we can still service and calibrate it. Talk to our team about spares or alternatives.

The GasTech S-Guard Series GIR-3000 is a single-source, dual-wavelength infrared gas detector for continuous monitoring in explosion-hazardous areas. It provides a 4-20mA analog output with remote alarm, fault and calibration signals.

See how the new Workplace Exposure Limits (WEL) affect this detector’s default alarm levels.

KEY BENEFITS

  •   Continuous detection in explosion-hazardous areas with flameproof structure
  •   State-of-the-art infrared detection principle
  •   Single-source, dual-wavelength self-compensating design
  •   Long service life of more than 5 years
  •   Low operating cost, maintenance free

+ more in the Description tab below

Self-Compensating Infrared Detection for Hazardous Areas

The GasTech Australia Smart Guard series S-Guard GIR-3000 is a single-source, dual-wavelength instrument. The sensing and reference elements are self-compensating for optical integrity and other signal inhibitors, ensuring reliable readings over the long term.

An industry-standard 4-20mA analog output provides remote alarm, fault and calibration signals, while RS-485 Modbus (isolated) serial communication makes it easy to configure a wider monitoring system. A built-in microprocessor delivers self-diagnosis and a rapid response time within 10 seconds.

Built with a flameproof structure for continuous detection in explosion-hazardous areas, the S-Guard operates even in oxygen-free environments and offers a long service life of more than five years with low, maintenance-free running costs.

Benefits

  •   Continuous detection in explosion-hazardous areas with flameproof structure
  •   State-of-the-art infrared detection principle
  •   Single-source, dual-wavelength self-compensating design
  •   Long service life of more than 5 years
  •   Low operating cost, maintenance free
  •   Operates in no-oxygen environments
  •   Self-diagnosis with built-in microprocessor
  •   Rapid response time within 10 seconds
  •   Two-stage alarm with one fault relay output
  •   4-20mA output with RS-485 Modbus serial communication
Detection Principle
Infrared, single source dual wavelength
Output Signal
4-20mA DC
Communication
RS-485 Modbus (isolated) serial
Response Time
Within 10 seconds
Service Life
More than 5 years
Display
Built-in backlit LCD
Alarms
Two stage alarm with one fault relay output
Calibration
Auto calibration and program setting with magnet control
Structure
Flameproof for explosion-hazardous areas
Model 67-9090-CO2
S-Guard IR Smart Transmitter, 4-20mA, 0-100% LEL IECEx
Model 67-9090-R-CO2
S-Guard Smart IR Remote Sensors Smart Transmitter, 4-20mA, 0-100% LEL IECEx

It uses a single-source, dual-wavelength infrared detection principle, with self-compensating sensing and reference elements for optical integrity.

Yes. The infrared detection principle allows the S-Guard to operate reliably in oxygen-free environments, unlike catalytic detectors.

It provides an industry-standard 4-20mA DC analog output for remote alarm, fault and calibration signals, plus RS-485 Modbus (isolated) serial communication.

It offers a long service life of more than five years with low, maintenance-free operating costs.

The S-Guard delivers a rapid response time within 10 seconds, supported by a built-in microprocessor with self-diagnosis.

From 1 December 2026, Safe Work Australia’s Workplace Exposure Limits (WEL) replace the old Workplace Exposure Standards (WES). The table below shows the old and new limits for the gas the S-Guard CO₂ detects, and the default alarm levels we set on new units.

Why fixed detectors are different: the WEL limits how much gas a person breathes over a shift (8 hours) or 15 minutes. A fixed detector watches one spot, not a person, so it can’t measure anyone’s exposure. Its alarms warn that gas is present in the area. We still base our default alarms on the WEL, so they line up with the limits your workers need to stay under. Your site sets its alarm levels, based on your own risk assessment. Tell us your own levels when you order, or we’ll set our defaults.

Gas Before 1 Dec (WES) From 1 Dec (WEL) Default low alarm Default high alarm
Carbon Dioxide (CO₂) 5,000 (8hr), 30,000 (15min) No change 5,000 20,000

All limits and alarms in ppm. The CO₂ limit hasn’t changed, so the S-Guard CO₂’s alarm levels stay the same.

Information as at 24 November 2026. See the full list of limits on the Safe Work Australia website.

No results found.

Recommended products

Trusted by

Contact Us

Can’t find what you’re looking for? Our team is happy to help.