Titan 2
Fixed Benzene Gas Monitor
The Titan 2 by ION Science is a fixed benzene monitor with world leading benzene detection technology. Using the new MiniPID T2 10.0 eV sensor and a unique sampling method that eliminates interference from toluene, xylene and methane, it detects benzene from 0.02 ppm (20 ppb) up to 20 ppm, sampling once a minute. Results show on a clear graphical LCD with bright LED alarm indicators, and output through 4-20 mA, RS485 Modbus or USB. ATEX, IECEx and QPS approved and rated IP65, it suits oil and gas, bulk storage, chemical manufacturing and asphalt production.
KEY BENEFITS
- Benzene specific detection within a typical petrochemical matrix, eliminating interference from toluene, xylene and methane
- Detects benzene from 0.02 ppm (20 ppb) up to 20 ppm, with 10 ppb resolution
- Samples once a minute for continuous benzene monitoring
- New MiniPID T2 10.0 eV sensor delivers improved sensitivity, reliability and overall performance compared to the original Titan
- Piezo electric micro pump combines silent operation with millisecond response and high precision
+ more in the Description tab below
World Leading Benzene Detection
Benzene is a known human carcinogen. Long term exposure is linked to leukaemia, especially acute myeloid leukaemia. Exposure limits are low, and in the EU the limit dropped to 0.2 ppm in April 2026. Monitoring it reliably takes a fixed instrument that can detect benzene accurately at very low levels, in places where other aromatic compounds are also present.
Most fixed PID detectors can’t do this. A standard 10.6 eV PID detects all ionisable compounds, giving a total VOC reading that includes toluene, xylene and other aromatics as well as benzene. In a refinery or chemical plant, that combined reading doesn’t tell you how much benzene is actually there.
The Titan 2 is built for this problem. Its new MiniPID T2 10.0 eV sensor and unique sampling method eliminate interfering gases such as toluene, xylene and methane. The result is a benzene specific reading within a typical petrochemical gas matrix.
Continuous Monitoring at Low Levels
The Titan 2 detects benzene from 0.02 ppm (20 ppb) up to 20 ppm, with 10 ppb resolution and accuracy of ±50 ppb or ±10%, whichever is greater. It takes a sample once a minute, giving a steady stream of data.
Internally regulated heating keeps operation stable in extreme temperatures. The piezo electric micro pump combines silent operation with millisecond response and high precision.
Designed for Easy Installation and Service
The Titan 2’s modular design means the Ex d case can be installed well before commissioning. The service module is a plug and play cartridge that can be removed and replaced quickly, keeping downtime to a minimum.
Some components are serviced at six months and others at 12 months. Data is stored on board for at least six months and can be downloaded via USB for analysis. Registering the Titan 2 online extends the warranty to up to two years.
Where It’s Used
The Titan 2 suits oil and gas, bulk storage facilities, chemical manufacturing and processing, and asphalt production. It can also be used to check the performance of purification systems and vapour recovery units (VRU).
It’s ATEX, IECEx and QPS approved for hazardous areas, and its IP65 enclosure protects against dust and water, so it keeps working in dusty or humid conditions.
Benefits
- Benzene specific detection within a typical petrochemical matrix, eliminating interference from toluene, xylene and methane
- Detects benzene from 0.02 ppm (20 ppb) up to 20 ppm, with 10 ppb resolution
- Samples once a minute for continuous benzene monitoring
- New MiniPID T2 10.0 eV sensor delivers improved sensitivity, reliability and overall performance compared to the original Titan
- Piezo electric micro pump combines silent operation with millisecond response and high precision
- Plug and play service cartridge can be swapped quickly, keeping downtime to a minimum
- At least six months of data storage on a 2 GB card, downloadable via USB for analysis
- Two relay outputs configurable as normally open or normally closed for alarm system integration
- Supports 4-20 mA, RS485 Modbus (ASCII or RTU) and micro USB for flexible integration into existing SCADA and DCS systems
- Can be used to assess the performance of vapour recovery units (VRU) and purification systems alongside continuous area monitoring
Sensor type
MiniPID T2 10.0 eV
Selectivity
Benzene-specific within petrochemical matrix. Eliminates interference from toluene, xylene and methane
Detection range
0.02 to 20 ppm
Resolution
0.01 ppm (10 ppb)
Lower detection limit
0.02 ppm (20 ppb)
Accuracy
±50 ppb or ±10% whichever is greater
Sampling frequency
1 sample per minute
Pump type
Piezo electric micro pump
Flow rate
Minimum 100 ml/min
Temperature stability
Internally heated
Display
64 x 128 pixel graphical LCD with backlight and LED indicators
Menu control
Two magnetic switches for contactless operation
Operating temperature
-20°C to +50°C (recommended)
Humidity
0 to 99% RH
IP rating
IP65
Power supply
24 V DC at 3.2 A (recommended). Maximum 32 V DC at 2.4 A. Minimum 19 V DC at 4.0 A
Communication
Isolated 4-20 mA, isolated RS485 Modbus ASCII or RTU, micro USB
Relay outputs
Two isolated voltage-free relays, 24 V DC at 1.25 A, configurable as normally open or normally closed
Data storage
On board 2 GB MMC, minimum six months
Cable entry
Two 3/4-inch NPT gland threads
Sample line
Maximum 10 m PTFE, 6 mm OD, 4 mm ID
Weight
15 kg
Dimensions
219 x 219 x 172 mm
Certifications
ATEX FTZU 14 ATEX 0172X II 2G Ex db IIB+H2 T4 Gb. IECEx FTZU 14.0030X Ex db IIB+H2 T4 Gb. QPS LR1621-1 Ex db IIB+H2 T4 Gb, AEx db IIB+H2 T4 Gb. All Ta -20°C to +55°C
Service interval
6 months: PID lamp, electrode stack, inline filter, VRV restrictor, hydrophobic and carbon filter. 12 months: the same items plus the AirSep filter
Warranty
Extendable to up to 2 years when registered online
Benzene
C6H6
- Chemical Manufacturing
- Energy (Oil & Gas)
- Landfill & Remediation
- Mining & Minerals
- Power Generation & BESS
- Technology & Semiconductor
- Water & Wastewater
A standard PID detects all ionisable compounds, including toluene, xylene and other aromatics often found with benzene. The Titan 2's new MiniPID T2 10.0 eV sensor and unique sampling method eliminate interfering gases such as toluene, xylene and methane, giving a benzene specific reading within a typical petrochemical matrix.
The Titan 2 samples once a minute, giving a continuous stream of benzene readings.
The Titan 2 outputs an isolated 4-20 mA analogue signal, isolated RS485 Modbus (ASCII or RTU) and micro USB for direct PC connection. Two isolated relay outputs configurable as normally open or normally closed are also available for alarm system integration.
The maximum sample line length is 10 metres using 6 mm OD, 4 mm ID PTFE tubing.
The service module is a plug and play cartridge that can be removed and replaced quickly, keeping downtime to a minimum. Some components are serviced at six months and others at 12 months.
Yes. As well as monitoring the air for worker safety, the Titan 2 can be used to check the performance of purification systems and vapour recovery units (VRU).
Trusted by







Contact Us
Can’t find what you’re looking for? Our team is happy to help.