D-Guard²
Fixed Gas Detectors
The D-Guard² is Gastech’s own fixed digital gas detector, designed from the ground up for reliable, accurate detection of 18 gases from a single platform. It runs on a two wire 4-20 mA loop, including for NDIR methane and carbon dioxide, so more detectors run from smaller power supplies on thinner cable. Group I and Group II intrinsic safety certification covers underground coal and surface industry with the same detector. Setup and calibration are non intrusive, using a magnetic stylus, and the detector self tests on a timer or on command through HART.
KEY BENEFITS
- Two wire loop powered design lets a larger detector count run from a smaller power supply, cutting cable diameter and barrier complexity on medium and large installations
- Group I and Group II intrinsic safety on one platform, so underground coal and surface plant use the same detector and the same spares holding
- 18 gases from a single board, configured through the interface, keeping engineering and stock simple
- Non intrusive setup and calibration with a magnetic stylus, with no need to open the enclosure
- Integrated dynamic response testing measures actual response time, ahead of standards moving toward requiring it
+ more in the Description tab below
Two Wire Loop Power Changes the Install Cost
Most fixed gas detection needs three or four wires, with power going one way and signal the other. The D-Guard² runs power and signal on the same two wire 4-20 mA loop. That includes NDIR methane and carbon dioxide, which usually draw too much current for loop power.
That has three practical effects. More detectors run from one power supply, cable diameter comes down, and barrier arrangements get simpler. On a small install the saving is modest. Across a plant with dozens of detection points, it changes the install budget and the running cost.
Certified for Underground Coal and Surface Plant
This is the specification that sets the D-Guard² apart in the Australian market.
It’s certified IECEx Ex ia I Ma for Group I mining, and Ex ia IIC T4 Ga for Group II surface industry. The LEL, methane and CO2 versions are certified Ex ia IIB T4 Ga. It also holds ATEX Ex I M1 and II 1G certification, and an ANZEx certificate.
A business running an underground operation and a surface plant often holds two different detectors, two sets of spares and two calibration procedures. The D-Guard² can cover both.
18 Gases, One Board
The D-Guard² uses a single electronics board across toxic gases, oxygen, flammable gases and carbon dioxide. Sensors are 4 series plug in units, and configuration is done through the interface.
For a maintenance team, that means one detector type to learn and one spares line to hold. It’s the same whether the point is monitoring hydrogen sulphide at a wastewater plant, methane underground, phosphine in fumigation or ethylene oxide in a sterilisation area.
NDIR is used for methane and carbon dioxide, giving long sensor life with no poisoning risk.
Calibrate It Without Opening It
Setup and calibration are done with a magnetic stylus against the closed housing, so nothing is unscrewed or exposed. On screen prompts guide the technician through calibration and configuration, which reduces the chance of a mistake by someone who calibrates a detector twice a year rather than twice a day.
A detector isolate feature lets a point be taken out of service for maintenance without triggering a system alarm.
It Tells You When It’s Not Working
A gas detector that has silently failed is worse than no detector, because the plant believes it’s protected.
The D-Guard² runs a sensor self test on a timer, or on demand over HART, and monitors its operating conditions continuously. Response time testing is built in too. It gives a real measurement of dynamic performance, rather than assuming a detector that responded last year still responds today. As standards begin to require this kind of testing, the D-Guard² is already equipped for it.
HART Gives You More Than a Number
A 4-20 mA loop carries one value. Optional HART 7.0 over the same two wires carries much more: real time gas readings, diagnostic information and remote sensor testing. Current loop rescaling and test mode can also be triggered remotely.
For a remote installation, that’s the difference between sending someone out to check a detector and checking it from the control room. HART is optional, so a straightforward install can do without it.
A Display You Can Actually Read
The display is a 400 x 240 pixel graphical backlit LCD, chosen for ultra low power draw so it works within the loop power budget. It’s readable from low light spaces right through to direct sunlight. Clear text and graphics make the reading and detector status obvious at a glance.
Built for Rough Conditions
The housing is a highly impact resistant, non conductive acetal plastic. It’s anti static, UV stable and chemically resistant, which suits intrinsically safe applications. It’s rated IP66 and IP68, tested to 1.2 metres for 1.5 hours.
Sensor temperature compensation, available on selected models, corrects both the zero point and the gas response as the temperature changes. The detector stays steady in clean air and accurate when gas is present. Drift is less than 3% signal loss over 12 months.
The certified operating range is -20°C to +70°C for Group IIC, and -20°C to +55°C for the NDIR versions and all other variants.
Certified or General Purpose
Two versions are available. The IECEx certified D-Guard² is for hazardous areas. The D-Guard²G is a general purpose version for safe area installations, at lower cost, with the same function and interface. The D-Guard²G also offers hydrogen tolerant CO sensors.
Our engineering team can confirm which version your installation calls for.
Where It’s Used
Underground coal mining, mineral processing and surface plant, wastewater treatment and pump stations, landfill gas monitoring, chemical manufacturing and storage, oil and gas processing, fumigation and grain handling, sterilisation areas in healthcare, semiconductor and electronics manufacturing, carparks and plant rooms, breweries and beverage production, and power generation.
Benefits
- Two wire loop powered design lets a larger detector count run from a smaller power supply, cutting cable diameter and barrier complexity on medium and large installations
- Group I and Group II intrinsic safety on one platform, so underground coal and surface plant use the same detector and the same spares holding
- 18 gases from a single board, configured through the interface, keeping engineering and stock simple
- Non intrusive setup and calibration with a magnetic stylus, with no need to open the enclosure
- Integrated dynamic response testing measures actual response time, ahead of standards moving toward requiring it
- Sensor self test runs on a timer or on demand over HART, so a failed sensor reports itself rather than waiting for a service visit
- Detector isolate feature takes a point out of service for maintenance without a system alarm
- Sensor temperature compensation holds both zero and span steady as ambient temperature moves, available on selected models
- IP66 and IP68 rated, tested to 1.2 metres for 1.5 hours
- Drift under 3 percent signal loss across 12 months, which keeps calibration intervals long and predictable
Analogue output
Two wire 4 to 20 mA
Digital communication
HART 7.0 over the two wire loop, on selected models
Indication
400 x 240 pixel graphical backlit LCD
Input power
Group IIB 13 to 28 V, Group IIC 13 to 28 V, Group I 13 to 22 V
Response time
T90 typically under 40 seconds for toxic gases and under 10 seconds for methane, cell dependent
Certified operating temperature
Minus 20°C to plus 70°C for Group IIC. Minus 20°C to plus 55°C for the NDIR version and other variants
Humidity range
15 to 90% non-condensing
Sensor style
4 series plug in sensors
Calibration
Non-intrusive, magnetic stylus
Sensor self test
Timed or HART triggered, with continuous operating condition monitoring
Response testing
Integrated dynamic response testing
Drift
Under 3% signal loss per 12 months
Dimensions
120 x 120 x 95 mm
Enclosure
Highly impact resistant, non conductive, anti static, UV stable, chemically resistant acetal plastic
Intrinsic safety certification
IECEx BAS 15.0013: Ex ia I Ma (-20°C to +55°C), all versions. Ex ia IIC T4 Ga (-20°C to +70°C), all except LEL, CH4 and CO2 versions. Ex ia IIB T4 Ga (-20°C to +55°C), LEL, CH4 and CO2 versions. ATEX Baseefa15ATEX0029: Ex I M1 / II 1G
Australian certification
ANZEx 18.2002
IP rating
IP66 and IP68 (1.2 m for 1.5 hours)
Warranty
2 years on the instrument. Sensor warranty varies by cell
Ethylene Oxide (ETO)
C2H4O
Propane
C3H8
Methane
CH4
Chlorine
Cl2
Carbon Monoxide
CO
Carbon Dioxide
CO2
Hydrogen Sulphide
H2S
Hydrogen Chloride
HCl
Hydrogen Cyanide
HCN
Hydrogen Fluoride
HF
Ammonia
NH3
Nitric Oxide
NO
Nitrogen Dioxide
NO2
Oxygen
O2
Ozone
O3
Phosphine
PH3
Sulphur Dioxide
SO2
- Aviation & Transportation
- Carpark & HVAC
- Chemical Manufacturing
- Confined Space & Compliance
- Energy (Oil & Gas)
- Food & Beverage
- Landfill & Remediation
- Marine & Maritime
- Medical & Healthcare
- Mining & Minerals
- Power Generation & BESS
- Technology & Semiconductor
- Water & Wastewater
The D-Guard² detects 18 gases, covering flammable gases, toxic gases, oxygen and carbon dioxide. Several gases come in more than one range. Talk to our Technical Consultants about other gases and ranges.
Yes. All versions are certified IECEx Ex ia I Ma for Group I mining, alongside Group II certification for surface industry. It also holds an ANZEx certificate.
No, it is two wire loop powered including for NDIR methane and carbon dioxide, so more detectors run from a smaller supply on thinner cable.
Non intrusively, with a magnetic stylus against the closed housing. On screen prompts guide the technician through the process, so there's no need to open the enclosure.
Real time readings, diagnostics, remote sensor testing and current loop rescaling, all over the same two wires.
Yes. The D-Guard²G is a general purpose version for safe area installations, at lower cost, with the same function and interface.
Trusted by







Contact Us
Can’t find what you’re looking for? Our team is happy to help.