Skip to main contentSkip to footer

B-Guard²

Modular Fixed Gas Detector

The B-Guard² is Gastech’s modular fixed gas detector, powered by G-Pod. It’s compliance without complexity: everything you need, nothing you don’t. One housing fits a wide range of toxic, flammable and asphyxiant gases. A quadrant LED ring shows detector status from across the site, and built in relays connect straight to your existing safety system. It comes in two versions: certified for hazardous areas, and general purpose for areas without a flammable atmosphere.

KEY BENEFITS

  •   Visual safety at a glance, with a quadrant LED ring that shows normal, warning and alarm status
  •   Powered by G-Pod, so one housing fits a wide range of toxic, flammable and asphyxiant gases
  •   Rapid plug and play sensor swaps keep downtime to a minimum
  •   Calibration data is stored on the G-Pod, so sensors can be calibrated off site and fitted ready to go
  •   Low cost of ownership, with fast servicing and fewer spares on the shelf

+ more in the Description tab below

Visual Safety at a Glance

Most fixed detectors make you walk up and read a display. The B-Guard² uses a quadrant LED ring instead. Colour and position show normal operation, warnings and faults at a glance, from a distance and from different angles. Anyone on site can see the detector’s status. The LEDs also change colour as you set up and calibrate the detector, so the technician gets instant feedback.

One Fixed Gas Detector for a Wide Range of Gases

The B-Guard² is powered by G-Pod, Gastech’s plug in sensor cartridge. G-Pods cover electrochemical, catalytic, NDIR and MPS™ sensing for toxic, flammable and asphyxiant gases. The detector recognises the G-Pod as soon as it’s fitted.

One housing fits a wide range of gases. That means one detector type to specify, one install method and fewer spares on the shelf.

Low Cost of Ownership

Sensor changes are where fixed detection costs time and money. With the B-Guard², you swap the G-Pod and the detector is back online. Configuration and calibration data are stored on the G-Pod itself, so sensors can be calibrated off site and fitted ready to go, without removing the detector from the wall.

The face plate is also field replaceable. Setup and calibration are non intrusive, using a magnetic service tool, so the housing stays closed.

Less time on site, fewer spares on the shelf and a 5 year detector warranty keep running costs down over the life of the detector.

Certified or General Purpose

Two versions are available. Choose based on whether the area has a flammable atmosphere.

Certified General purpose
Use in Hazardous areas with a flammable atmosphere Areas without a flammable atmosphere, including toxic gas monitoring such as CO
Housing 316L stainless steel 316L stainless steel or aluminium
Certification IECEx and ATEX Ex db IIC T4 Gb, EMC BS EN 50270:2015 EMC BS EN 50270:2015 (not for hazardous areas)
Weight 3.4 kg including G-Pod 3.4 kg (stainless steel), 2.8 kg (aluminium), including G-Pod

Not sure which you need? Talk to our Technical Consultants.

Compliance Without Complexity

Relay outputs are built in, so the B-Guard² can drive alarms, beacons and shutdowns directly. The 4 to 20 mA output works as source or sink, and HART 7 and Modbus RTU (RS-485) come as standard.

That makes it a simple, cost effective replacement for outdated or unsupported detectors, without changing your panel, PLC or control system. Everything you need for compliance level monitoring, nothing you don’t.

Built Tough for Hazardous Areas

The certified B-Guard² carries IECEx and ATEX Ex d flameproof certification in a 316L stainless steel housing. Both versions are rated IP66 and IP68 (1.2 m for 30 minutes) and operate from -40°C to +70°C, with individual G-Pod ranges listed in the Gases tab.

IP66 and IP68 Explained

The IP rating tells you how well the housing keeps out dust and water. The B-Guard² carries two.

IP6X, dust tight: tested for 8 hours in circulating dust, with no dust getting inside.
IPX6, powerful water jets: tested with a 100 litre per minute jet from 2.5 to 3 m, with no water getting inside.
IPX8, immersion: rated for 1.2 m underwater for 30 minutes, with no water getting inside. The housing was tested for 1 hour.

Both the stainless steel and aluminium housings were tested and passed to IEC 60529 by Austest Laboratories. To keep the rating in the field, use glands and stopping plugs that maintain the marked IP rating.

What the Certification Means

The certified B-Guard² (part number 65-2100-EXS) is flameproof, or Ex d. If gas inside the housing ever ignites, the enclosure contains it so it can’t ignite the atmosphere outside. That makes it safe to install in hazardous areas with a flammable atmosphere.

It’s certified under IECEx (SGS 25.0049X) and ATEX (SGS25ATEX0098X) to IEC 60079-0 and IEC 60079-1, marked Ex db IIC T4 Gb. In plain terms:

IIC: suitable for the most easily ignited gas group, including hydrogen
T4: surface temperature stays below 135°C
Gb: suitable for Zone 1 and Zone 2 hazardous areas

The certificates cover the electrochemical, MPS™, catalytic and NDIR versions. Maximum ambient temperature depends on the G-Pod fitted: up to +70°C for EC and MPS™, +60°C for NDIR and +55°C for catalytic.

Only the certified version is certified. A stainless steel B-Guard² isn’t hazardous area certified unless its rating plate says so.

Simple to Use, Easy to Service, Backed by Gastech

The B-Guard² is designed and built by Gastech in Australia. That means local supply, parts, service and training from our teams in WA, NSW and QLD, plus a 5 year warranty on the detector.

Where It’s Used

Mining and mineral processing, water and wastewater treatment, chemical manufacturing, oil and gas, power generation, food and beverage, landfill sites, and carparks and plant rooms.

Benefits

  •   Visual safety at a glance, with a quadrant LED ring that shows normal, warning and alarm status
  •   Powered by G-Pod, so one housing fits a wide range of toxic, flammable and asphyxiant gases
  •   Rapid plug and play sensor swaps keep downtime to a minimum
  •   Calibration data is stored on the G-Pod, so sensors can be calibrated off site and fitted ready to go
  •   Low cost of ownership, with fast servicing and fewer spares on the shelf
  •   Built in relay outputs connect to alarms and shutdowns with no add on modules
  •   4 to 20 mA source or sink, HART 7 and Modbus RTU as standard, for simple integration with existing systems
  •   Certified version for hazardous areas, with IECEx and ATEX Ex d flameproof certification
  •   General purpose version for areas without a flammable atmosphere, including toxic gas monitoring
  •   IP66 and IP68 rated, backed by Gastech with a 5 year detector warranty
Size (H x W x D)
199 x 118 x 120 mm
Housing: Certified
316L stainless steel
Housing: General purpose
316L stainless steel or aluminium
Weight: Certified
3.4 kg including G-Pod
Weight: General purpose
3.4 kg (stainless steel), 2.8 kg (aluminium), including G-Pod
G-Pod splash guard
Polyoxymethylene
Installation
Wall mount (two 9 mm through holes) or pipe mount with pipe mounting kit
Ingress protection
IP66 and IP68 (1.2 m for 30 minutes)
Operating temperature
-40°C to +70°C (see Brochure for individual G-Pod ranges)
Humidity range
5 to 95 %rh (see Brochure for individual G-Pod ranges)
Calibration
Automatic zero and span adjustment, non-intrusive using magnetic service tool
Power
14 to 32 VDC (if 4 to 20 mA load under 560 Ω), max 6.7 W
Indication
Quadrant LED ring and three LED indicators
Analogue output
4 to 20 mA current loop, source or sink
Digital communication
HART 7, Modbus RTU (RS-485)
IECEx (certified only)
Ex db IIC T4 Gb, -40°C to +70°C (EC and MPS), -40°C to +55°C (catalytic), -40°C to +60°C (NDIR)
ATEX (certified only)
II 2 G Ex db IIC T4 Gb
EMC (both versions)
BS EN 50270:2015
Warranty
5 years on detector, G-Pods 1 to 2 years depending on type
Ethylene (Ethene)
C2H4
Propane
C3H8
Butane
C4H10
Pentane
C5H12
Hexane
C6H14
Methane
CH4
Carbon Monoxide
CO
Carbon Dioxide
CO2
Hydrogen
H2
Hydrogen Sulphide
H2S
Hydrogen Cyanide
HCN
Ammonia
NH3
Nitric Oxide
NO
Nitrogen Dioxide
NO2
Oxygen
O2
Sulphur Dioxide
SO2
  • Carpark & HVAC
  • Chemical Manufacturing
  • Energy (Oil & Gas)
  • Food & Beverage
  • Landfill & Remediation
  • Mining & Minerals
  • Power Generation & BESS
  • Water & Wastewater
IECEx 357 KB
ATEX 343 KB

How many gases can the B-Guard² detect? 16 gases, using electrochemical, catalytic and NDIR G-Pods. Several gases come in more than one range. Talk to our Technical Consultants about your gas and range.

Yes, the certified version. It’s built tough for hazardous areas, with a 316L stainless steel housing and IECEx and ATEX Ex d flameproof certification.

Areas without a flammable atmosphere. It’s still suitable for toxic gas monitoring, such as CO, and comes in stainless steel or aluminium.

Swap the G-Pod. It’s a rapid plug and play change. The B-Guard² recognises the new G-Pod along with its stored configuration and calibration data, so downtime is kept to a minimum.

No. Setup and calibration use a magnetic service tool against the closed housing.

The quadrant LED ring gives you visual safety at a glance. Colour and position show normal operation, warnings and faults, so anyone on site can see the detector’s status.

Yes. It has built in relays, a 4 to 20 mA output (source or sink), HART 7 and Modbus RTU. That makes it a simple replacement for outdated or unsupported detectors.

5 years on the detector. G-Pods are covered for 1 to 2 years depending on type.

No, by design. The quadrant LED ring shows status from across the site, so there’s no need to walk up and read a screen. The reading goes to your control system via 4 to 20 mA, HART or Modbus.